Surgical Biphasic Defibrillator Monitor With Manual/AED Mode, ECG & Operating Room Ready
Surgical Biphasic Defibrillator Monitor Features:
This device offers critical dual functionality essential for the operating room. The Manual Mode provides the surgeon or anesthesiologist with precise, expert control over energy and timing for synchronized cardioversion, while the AED Mode is available for rapid, guided defibrillation by other staff in an unexpected cardiac arrest situation.
The design is explicitly tailored for the Surgical environment. This means the unit is likely robust, resistant to common OR fluids, designed for rapid deployment on a crash cart, and capable of functioning reliably despite potential electromagnetic interference from other surgical equipment.
The Biphasic waveform delivers a powerful, effective shock at lower energy levels than older technology. This is crucial for increasing first-shock success rates and minimizing myocardial damage, a key concern in sensitive surgical patients.
The device functions as a complete Defibrillator Monitor. It provides real-time ECG (electrocardiogram) readings, allowing clinicians to instantly diagnose the patient's rhythm (e.g., VF, VT) before, during, and after a shock. This integration ensures rapid decision-making and continuous patient assessment in a high-acuity setting.
Surgical Biphasic Defibrillator Monitor Technical Parameter:
Display | Screen Type: High-resolution display Screen Size: 7 inches(17.7 cm) diagonally Sweep Speed: 25mm/sec Information: Heart Rate,Lead/Pads, Alarm On/Off,Sp02,AED Functions and Prompts,Alarm Selection and Limits,Delivered Energy. |
Defibrillator | Waveform: Biphasic Charge Time: Less than 7 seconds with a new fully charged battery. Energy Display: Monitor display indicates both selected and delivered energy. Charge Prompt Type: Voice and visual prompts. Electrode Impedance Measurement Range:0-250 ohms. |
ECG Monitoring | Patient Connection: 3-lead ECG cable, or 5-lead ECG cable, paddles. Lead Selection: Displayed on monitor, paddles, I, 1I, III, AVR, AVL, AVF, V. ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor. Heart Rate: 20-300BPM. Heart Rate Alarm: On/Off displayed on monitor, user-selectable. Smart Alarms: Beeper/voice prompts indicate shockable rhythm. |
Battary | Type: Rechargeable,Ni-MH battery,12V. Operating Time: For a new, fully charged battery:100 defibrillator discharges , or 3 hours minimum of continuous ECG monitoring.Additional parameters will effect operating time with different functions. |
SpO2 Module | Measurement Range: 30~100%,±2% between 80%~90%, 0thers ±5% Alarm Range: User set high limit and low limit. Alarm Accuracy: ±10% within setting values. Alarm time Accuracy: less than 12 sec. |
Recorder | Paper: 50mm thermal. Speed: 12.5mm/sec,25mm/sec,50mm/sec. User-selectable 6-second delay. Printing Method:High-resolution, thermal print head. Print-out Modes: Manual or automatic, user-configurable. On/Off Control: Front panel and paddle. Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge. |
AED Mode | AED Function: Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts. Shockable Rhythms:Ventricular fibrillation with amplitude >=200uV, ventricular tachycardia with rates >=140bpm, and QRS complex wave duration >=140ms. Charge Control: Control on device front panel, press key on paddle. Prompts: Voice and visual prompts. |
Manual Mode | Energy Selection: Selectable at 2, 5, 7, 10, 20,30,50,70,100,150,200, 300, 360 joules. Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave."SYNC" message displayed on monitor. |
Surgical Biphasic Defibrillator Monitor Usage
Purpose: To treat sudden cardiac arrest (SCA) or perform controlled synchronized cardioversion during or immediately following surgical procedures. Anesthesiologists and surgeons require immediate access and full manual control.
Purpose: To monitor patients waking up from anesthesia, as they are at higher risk for cardiac arrhythmias or instability. The monitor provides continuous ECG monitoring and is ready for immediate manual defibrillation.
Purpose: Used as part of the resuscitation toolkit, often kept readily available on crash carts. These devices allow nurses and doctors to track subtle changes in the ECG rhythm and deliver an immediate, controlled electrical therapy if needed.
Purpose: For rapid stabilization and resuscitation of critically ill patients. The integrated monitor and printer are essential for making quick diagnoses and providing immediate patient documentation.