Portable AED Defibrillator Automated External Defibrillator With Voice CPR Guid For Public And Home Use
AED Defibrillator Automated External Defibrillator Feature:
AED Defibrillator Automated External Defibrillator Usage
BT-AED05 is a portable model, which can be equipped at home, in public places, or in the hospitals. It's easy and convenient to use when give first-aid to patient. Meanwhile, it has the function of automatic analyzing patient's ECG data, and then takes corresponding defibrillation energy level according to patient's current situation, which has greatly improved success rate, and maximum reduced damage to patient's heart.
AED Defibrillator Automated External Defibrillator Specification:
AED Defibrillator Automated External Defibrillator
Category |
Specification |
Output Energy Sequence(adult) |
Biphasic Truncated exponential 150/150/200(Default) 150/200/200 200/200/200 Note: the Energy sequence can be changed using the computer IR port. |
Energy Sequence(Pediatric) |
50/70/85(Default) 70/70/85 70/85/85 85/85/85 Note: the Energy sequence can be changed using the computer IR port. |
Charge Time Analysis Time |
10 sec. to 200 J 9 sec. |
The maximum time from the initiation of rhytlun analysis to readiness for maximum Energy discharge after 15 shocks. |
Less than 30 seconds |
The maximum time from initially switching power on to readiness for maximum Energy discharge after 15 shocks.. |
Less than 35seconds |
Audible Prompts |
19 audible prompts |
Visual Prompts |
LED/LCD |
Controls |
six buttons - On/Off, Shock, and 4 software-configurable buttons |
Output Energy Accuracy |
±15% into any impedance from 25 to 175Q |
The Maximum Voltage Output disabled when the PATIENT impedance is outside limits |
1800±20V 20.to 200Q |
Recovery of the ECG input after |
<10s |
AED Defibrillator Automated External Defibrillator Physical
Category |
Specification |
Dimensions |
225 x 200 x 85mm |
Weight |
2.0 kg |
Operating Temperature |
0°C to 40 °C |
Operating Humidity |
Relative humidity between 30% and 95% (non-condensing) |
Altitude |
-300 to 15,000 ft( -91m to 4573m) |
Pressure |
102.4kPa〜57.2kPa(768mmHg 〜429mmHg) |
Storage Temperature |
-20°C to 55 °C |
(without battery) |
|
Storage Humidity |
Up to 93% (non-condensing) |
(without battery) |
|
Particle and Water Ingress |
IP24 |
AED Defibrillator Automated External Defibrillator Electrical Isolation
Category |
Specification |
Power |
Unit operates on internal battery only |
External Electrical Connections |
No external devices are attached to the unit |
Risk Current Category |
Internally powered equipment with defibrillator-proof BF type patient applied part (as per definition of IEC 60601-1 standard) |